Hoy hablaré sobre las distintas utilidades para ver el estado de distintas controladoras raid.
No de todas que sería imposible, sino de las que monitorizo a diario y he encontrado aplicaciones para ello.

3ware

Su aplicación es tw_cli:


//backup> /c5 show all
/c5 Driver Version = 2.26.02.008
/c5 Model = 9550SXU-8LP
/c5 Available Memory = 112MB
/c5 Firmware Version = FE9X 3.04.00.005
/c5 Bios Version = BE9X 3.04.00.002
...
/c5 Number of Ports = 8
/c5 Number of Drives = 4
/c5 Number of Units = 1
/c5 Total Optimal Units = 1
/c5 Not Optimal Units = 0
...
/c5 Controller Bus Speed = 66 Mhz

Unit UnitType Status %RCmpl %V/I/M Stripe Size(GB) Cache AVrfy
------------------------------------------------------------------------------
u0 RAID-5 OK - - 64K 2095.44 ON OFF

Port Status Unit Size Blocks Serial
---------------------------------------------------------------
p0 OK u0 698.63 GB 1465149168 5QD0D6RW
p1 OK u0 698.63 GB 1465149168 5QD0D8B5
p2 OK u0 698.63 GB 1465149168 5QD0D6TG
p3 OK u0 698.63 GB 1465149168 5QD0D6TK
p4 NOT-PRESENT - - - -
..


ADAPTEC

Tenemos dos aplicaciones dependiendo la versión de la controladora, si tiene firmware antiguo utilizaremos afacli

Debemos crear primero /dev/afa0, para ello vemos major number con:
grep aac /proc/devices

y luego mknod /dev/afa0 c 0


:# afacli
CLI > open afa0
Executing: open "afa0"

AFA0> container list

Executing: container list
Num Total Oth Chunk Scsi Partition
Label Type Size Ctr Size Usage B:ID:L Offset:Size
----- ------ ------ --- ------ ------- ------ -------------
0 RAID-5 1.09TB 64KB Valid 0:00:0 64.0KB: 279GB
/dev/sda RAID5_5x300 0:01:0 64.0KB: 279GB
0:05:0 64.0KB: 279GB
0:03:0 64.0KB: 279GB
0:04:0 64.0KB: 279GB

1 Volume 279GB Valid 0:02:0 64.0KB: 279GB
/dev/sdb VOLUME_1X300



Para las controladoras con nuevo Firmware (lo sabran porque el afacli dice que la DLL que tiene es antigua) tendrán que usar arcconf utilidad de StorMan

~# /usr/src/prueba/usr/StorMan/arcconf GETCONFIG 1 AD
sh: /bin/sort: No existe el fichero o el directorio
Controllers found: 1
----------------------------------------------------------------------
Controller information
----------------------------------------------------------------------
Controller Status : Optimal
Channel description : SCSI
Controller Model : Adaptec 2020ZCR
Controller Serial Number : BAD0
Physical Slot : 2
Installed memory : 64 MB
Copyback : Disabled
Background consistency check : Disabled
Automatic Failover : Enabled
Defunct disk drive count : 0
Logical devices/Failed/Degraded : 2/0/0
--------------------------------------------------------
Controller Version Information
--------------------------------------------------------
BIOS : 5.1-0 (8458)
Firmware : 5.1-0 (8458)
Driver : 1.1-5 (2409)
Boot Flash : 0.0-0 (0)


Compaq Computer Corporation Smart Array

Utilizaremos arrayprobe

correo:~# /usr/bin/arrayprobe -r|tail -3
Logical drive 0 on controller /dev/cciss/c0d0 has state 0
Logical drive 1 on controller /dev/cciss/c0d0 has state 0
OK Arrayprobe All controllers ok


megaRAID

Utilizaremos la aplicación megaCLI


#:/opt/MegaRAID/MegaCli # /opt/MegaRAID/MegaCli/MegaCli -LDInfo -LALL -aALL


Adapter 0 -- Virtual Drive Information:
Virtual Disk: 0 (target id: 0)
Name:sistema
RAID Level: Primary-1, Secondary-0, RAID Level Qualifier-0
Size:714880MB
State: Optimal
Stripe Size: 64kB
Number Of Drives:2
Span Depth:1
Default Cache Policy: WriteThrough, ReadAheadNone, Direct, No Write Cache if Bad BBU
Current Cache Policy: WriteThrough, ReadAheadNone, Direct, No Write Cache if Bad BBU
Access Policy: Read/Write
Disk Cache Policy: Disk's Default


#:/opt/MegaRAID/MegaCli # /opt/MegaRAID/MegaCli/MegaCli -PDList -aALL

Adapter #0

Enclosure Device ID: N/A
Slot Number: 0
Device Id: 0
Sequence Number: 2
...
Last Predictive Failure Event Seq Number: 0
Raw Size: 715404MB [0x575466f0 Sectors]
...
Inquiry Data: ATA ST3750640NS E 3QD0XYL2

Enclosure Device ID: N/A
Slot Number: 1
Device Id: 1
Sequence Number: 2
...
Last Predictive Failure Event Seq Number: 0
Raw Size: 715404MB [0x575466f0 Sectors]
...
Connected Port Number: 1
Inquiry Data: ATA ST3750640NS E 3QD0ZKAX



Para algunas ADAPTEC, ADAPTEC DPT, SmartRaid V hay que utilizar dpt-i2o-raidutils / raidutils), de estas no tengo ejemplo.

Y finalmente para el raid por software:

~# mdadm --detail /dev/md0
/dev/md0:
Version : 00.90.01
Creation Time : Fri Jul 11 11:46:30 2008
Raid Level : raid1
Array Size : 995904 (972.73 MiB 1019.81 MB)
Device Size : 995904 (972.73 MiB 1019.81 MB)
Raid Devices : 2
Total Devices : 2
Preferred Minor : 0
Persistence : Superblock is persistent

Update Time : Sat Jul 12 06:25:46 2008
State : clean
Active Devices : 2
Working Devices : 2
Failed Devices : 0
Spare Devices : 0

UUID : cc3a522e:25fd72ba:1f0687a3:f9661a16
Events : 0.34

Number Major Minor RaidDevice State
0 8 17 0 active sync /dev/sdb1
1 8 33 1 active sync /dev/sdc1


y otro comando para saber las unidades no óptimas:

cat /proc/mdstat | egrep '(U_|_U)' | wc -l